Ul 60950 1 pdf software

Designing for compliance to ul 60950 1 2nd edition, cancsac 22. Printed board cemented joint program based on uliec 609501. Secure pdfs can be opened on one computer per user license. Iecee takes no responsibility for and will not assume liability for damages resulting from the readers interpretation of the reproduced material. Iec 603351 annex r software evaluation software shall be evaluated in accordance with the following clauses of annex h of iec 607301, as modified below. Designing for compliance to ul 609501 2nd edition, cancsac 22. This national standard is based on publication iec 609501, second. In iec terminology, safety is defined as an acceptable level of risk.

Ul 609501 information technology equipment safety purcell. Components not certified are used in accordance with their ratings. Printed board cemented joint program based on uliec. Our speed, expertise, and global network of labs will get your it equipment into more countries in less time than ever before. Iecenulcsa 60950 safety of information technology equipment is one of the worlds most widelyused electrical product safety standards. The ul 609501 standard is applicable to mainspowered or batterypowered information technology equipment, including electrical business equipment and associated equipment, with a rated voltage not exceeding 600 v and designed to be installed in accordance with the canadian electrical code, part i, csa c22. Addition of a continuity check tests based upon requirements in ul 609501. This switch shall be located where it is easily accessible to a user whose body part or clothing may be caught at the feed opening. Information technology and telecommunications equipment.

Safety standard iec 623681 to replace iec 609501 and iec. The iec 623681 safety standard was developed to converge these two standards with specific criteria based on requirements that take into account the energy sources, safeguards and the intended user to ensure safety. Ul 609501 information technology equipment safety part 1. Ul standard for safety for information technology equipment safety part 1. If a manual voltage selector is not operatoraccessible, the marking shall. The ul 60950 1 standard is applicable to mainspowered or batterypowered information technology equipment, including electrical business equipment and associated equipment, with a rated voltage not exceeding 600 v and designed to be installed in accordance with the canadian electrical code, part i, csa c22. General requirements binational standard, with ul 609501. Prepare for a smooth transition from legacy standards 60065 and 609501, to 623681. Originally the dow was june 2019, but was changed to december. Designing for compliance to ul 609501iec 609501csa 609501. This part of iec 60950 applies to information technology equipment intended to supply and receive operating power via a telecommunication network, where the voltage exceeds the limits for tnv circuits. This national standard is based on publication iec 609501, second edition. In order to open a secure pdf, you will need to install the fileopen plugin and register your computer. Iecenulcsa 60065, audio, video and similar electronic apparatus, and iecenulcsa 609501, information technology equipment.

This blog tells manufacturers everything they need to know about the changes. Safety standard iec 623681 to replace iec 609501 and iec 60065. Join underwriters laboratories for our newly developed and redesigned workshop on information technology and communications. Dielectric withstand test is only option for checking insulation. Page 1 of 10 e475124a2ul ul test report and procedure ul 609501, 2nd edition, 20141014 information technology equipment safety part 1. En 609501 information technology equipment safety part 1. Ul 609501 information technology equipment safety part. Ul standards for safety are developed and maintained in the standard. Ul 607301 automatic electrical controls for household. Software is relied upon for meeting safety requirements related to mechanical, fire and shock. Additional user licenses are available for purchase. Underwriters laboratories new new designs, old current production without major changes. Purchase ul standards online official ul standards sales.

The ul 609501 standard and tests take into account not only normal operating conditions of the equipment, but also likely fault conditions, consequential faults, foreseeable misuse and external influences such as temperature, altitude, pollution, moisture, as well as over voltages on a main supply, telecom network or cable network. An internet connection is required to open a secure pdf. Limiter may be of the automatic reset or of the manual reset type. The new standard is iec 62368, which will replace 60065 audiovideo and 60950 it for external power supplies. Measured between patient leads and mains reference. Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. Iec 62368 1 was published in europe during the second half of 2014. Multimedia products are increasingly falling under both iec 60065 av equipment and iec 609501 it equipment. Designing for compliance to ul 60950 1 2nd edition, cancsac22.

December 2020 is the date of withdrawal dow of the standards to supersede iec 60065 and iec 60950 1. Ul llc is a global safety certification company headquartered in northbrook, illinois. Rackmount power distribution units and ul 609501martin. If a surge suppressor is used in a primary circuit, it shall be a vdr and it shall comply with annex q. Ul 61010 replaces ul 508 for industrial power supplies norms.

In the complex, fastpaced technology market, its critical to stay current with the technical issues affecting product safety around the world. The ul 60950 1 standard and tests take into account not only normal operating conditions of the equipment, but also likely fault conditions, consequential faults, foreseeable misuse and external influences such as temperature, altitude, pollution, moisture, as well as over voltages on a main supply, telecom network or cable network. Ul 623681 2012feb17 ul standard for safety audovdeo nformaton and communcaton technology equpmentpart 1 safety requrementsfrst edton reprnt wth revsons through and ncludng march 8 2012. Iecul 606011 3rd edition, iecul 603351, iec 605981, iec ul 609501 patient leakage general leakage on leads that have a patient connection. Ul 60950 1 standard on information technology equipment safety. Ul 609501, 2nd edition, 20141014 information technology equipment safety part 1. Iecul 606011 3rd edition the leakage current test is run under varying fault conditions shown in the leakage network figure open neutral.

Ul 607301 automatic electrical controls for household and. The history of the 60950 standards sets and a bit of the future. Ul 1973, batteries for use in light electric rail ler. Iecul 60950 certification our speed, expertise, and global network of labs will get your it equipment into more countries in less time than ever before. This national standard is based on publication iec 609501, first.

Ul 609501 standard on information technology equipment safety. This is consistent with the intention of ul requirements to reduce the risk of fire, shock or injury to persons. Iec 609501 information technology equipment safety. Ul 609501 information technology equipment safety composter. Established in 1894 as the underwriters electrical bureau a bureau of the national board of fire underwriters, it was known throughout the 20th century as underwriters laboratories and participated in the safety analysis of many of that centurys new technologies.

Iec 607301 annex h requirements for electronic controls this chapter centers around table h. Ul consumer technology laboratories and dedicated test engineers are strategically located in major technology hubs so we can be closer to you. Test report iec 609501 information technology equipment. Iec 609501 and iec 60065 approvals will be replaced by one approval iec 623681 in december 2020. March 2007 information technology equipment safety part 1. The contents of the corrigendum of august 2003 have been included in this copy. Such battery packs that rely on solidstate circuits and software controls as safeguards shall comply with ul 1973 requirements for system safety. Iec 609501 information technology equipment safety part 1. Secure pdfs are encrypted with digital rights management drm software.

Join ul for our newly developed and redesigned workshop on information technology and communications equipment. General requirements canadian electrical code, part ii, csa c22. Iec 623681 was published in europe during the second half of 2014. When you complete the workshop, you will have information you need to design for compliance to national and international standards widely used in the industry. This new standard applies to a broad range of hightech products from consumer electronics to office equipment and offers greater. Understanding isolator standards and certification to meet. The hazard based standard, en 623681, will supersede en. We can help you plan ahead to ensure your products carry the updated certification and to help you avoid costly delays. Ul 6095022 information technology equipment safety. The history of the 60950 standards sets ite safety.

December 2000 practical application guide safety of information technology equipment, including electrical business equipment. Iecee takes no responsibility for and will not assume liability for damages resulting from the readers interpretation of the reproduced material due to its placement. Your experienced ul instructors will cover a broad range of technical topics within ul 609501iec 609501csa 609501. Designing for compliance to ul 609501 2nd edition, cancsac22. Page 1 of 10 e475124a2 ul ul test report and procedure ul 60950 1, 2nd edition, 20141014 information technology equipment safety part 1. This national standard is based on publication iec 609501, first edition.

The test is based upon ul 609501 electric strength test criteria. Test report iec 609501 andor en 609501, first edition. Iec 609501 information technology equipment safety part. This is passmark burnin test software which continuously sending and receiving usb, display port, lan, audio signals in and out. This part 21 of iec 60950 is intended to be used with iec 609501. Comply with iec 60950 1 or relevant component standard see appended tables 1. We offer a comprehensive array of regulatory and compliance testing services that can be tailored to meet your needs. Comply with iec 609501 or relevant component standard see appended tables 1. December 2020 is the date of withdrawal dow of the standards to supersede iec 60065 and iec 609501. Compliance to smart grid standard for systems connected to a smart grid. Ul609501 is a relatively new underwriters laboratory ul standard that applies to information technology equipment installed and implemented in the data center. This standard is applicable to mainspowered or batterypowered information technology equipment, including electrical business equipment and associated equipment, with a rated voltage not exceeding 600 v and designed to be installed in accordance with the canadian electrical code. June 24, 2008 ulcsa 609501 2nd edition charlie bayhi, p. General requirements, ul 609501 second edition, dated march 27, 2007 summary of topics this is the second edition of the binational standard and is based on iec 609501, second edition.

306 718 870 1507 511 171 1082 715 1001 1256 1255 418 279 364 667 1277 172 1379 258 373 435 199 70 1354 299 911 691 139 550 191 1051 412 1457 1308 532 580 1359 1378 1336 411 45 525 630 859 1249 347 1011 298 474